Emergency Exit Width

Calculate the required width of an emergency exit, W = (population ÷ unit capacity) × 0.55, dividing the population to be discharged by the capacity of people per exit unit and multiplying by one unit's width (0.55 m). The result, in metres, sizes doors, corridors, stairs and ramps of escape routes by the exit-unit criterion of fire safety codes. The capacity per unit varies with the type of exit (door, stair, ramp) and the occupancy. Enter the population and the capacity per exit unit.

Resultado

Largura de saída de emergência

As normas brasileiras de segurança contra incêndio (como a saída de emergência da ABNT NBR 9077 e as instruções técnicas dos corpos de bombeiros) dimensionam saídas pelo conceito de unidade de passagem: a largura mínima (0,55 m) por onde uma fila de pessoas consegue passar. A largura necessária sai de L = (população ÷ capacidade da unidade) × 0,55, onde a população é o número de pessoas que aquela saída precisa escoar (calculado pela área e pela densidade de ocupação típica do uso) e a capacidade da unidade é quantas pessoas cada unidade de passagem comporta — um valor tabelado que depende do tipo de saída: portas e corredores (acesso) escoam mais pessoas por unidade que escadas e rampas (onde o movimento é mais lento e arriscado), e o número também varia com a ocupação (uma escola difere de um hospital ou de um teatro). O resultado, em metros, é a largura mínima de portas, corredores, escadas e rampas das rotas de fuga; arredonda-se sempre para cima ao número inteiro de unidades e respeitam-se larguras mínimas absolutas. Dimensionar bem é vital: saídas estreitas demais criam gargalos que aumentam o tempo de evacuação e o risco de aglomeração e pisoteamento. Informe a população e a capacidade por unidade de passagem.

Related Tools

🚪

Evacuation Time

Estimate the evacuation time of a space, t = N ÷ (F × width), dividing the number of occupants N by the product of the specific people flow F (people per minute per metre) and the total exit width (m). The result, in minutes, is the movement time for everyone to pass through the exits — part of the total egress time used in escape route design and fire safety verification. Adequate exit widths and flows ensure evacuation occurs before conditions become untenable. Enter the number of occupants, the specific flow and the exit width.

💨

Smoke Plume Mass Flow

Calculate the mass flow of a fire's smoke plume by the Heskestad correlation, ṁ = 0.071·Q̇_c^(1/3)·z^(5/3), from the convective part of the heat release rate Q̇_c (kW) and the height above the fire base z (m). The result, in kg/s, is the amount of hot gases and smoke rising and accumulating, governing the design of smoke control and exhaust systems (mechanical or natural) that keep a smoke-free layer for safe evacuation. The flow grows strongly with height. Enter the convective heat fraction and the height.

🔥

Specific Fire Load

Calculate the specific fire load of a space, q = (mass × LHV) ÷ area, dividing the total energy of the combustible materials (mass × lower heating value) by the floor area. The result, in MJ/m², is the heat that would be released per unit area if all the material burned — the parameter that classifies a building's fire risk and sets protection requirements (fire resistance, exits, sprinklers) in fire codes. The higher the fire load, the more severe the potential fire. Enter the fuel mass, the heating value and the area.