Silo Horizontal Pressure (Janssen)
Calculate the horizontal pressure the stored product exerts on a silo wall by the Janssen equation, p_h = (γ·D)/(4·μ)·(1 − e^(−4·μ·K·z/D)), from the unit weight γ, diameter D, product-wall friction coefficient μ, lateral pressure ratio K and depth z. Horizontal pressure is the outward thrust grains apply against the silo walls — the load that sizes the wall for hoop tension (in cylindrical silos, the wall acts as a ring under internal pressure). It relates to vertical pressure by the lateral pressure ratio K (p_h = K·p_v), typically 0.3-0.6 for granular products and depending on the product's internal friction angle. Like vertical pressure, horizontal pressure tends to an asymptotic value with depth, by the same wall-friction effect of Janssen theory. Horizontal pressure is decisive for the thickness and reinforcement of concrete silo walls and the plating of steel silos, and rises significantly during DISCHARGE (dynamic overpressure), which codes handle with amplification factors. Enter the unit weight, diameter, friction coefficient, lateral pressure ratio and depth.
Result
—
Pressão horizontal em silo (Janssen)
A pressão horizontal que o produto exerce sobre a parede de um silo, pela teoria de Janssen, é p_h = (γ·D)/(4·μ)·(1 − e^(−4·μ·K·z/D)). É o empuxo que os grãos fazem para fora, contra as paredes — o carregamento que dimensiona a parede à tração circunferencial (em silos cilíndricos, a parede trabalha como um anel sob pressão interna, exatamente como um vaso de pressão). Ela se relaciona com a pressão vertical pela relação de pressão lateral K (p_h = K·p_v), que para produtos granulares fica tipicamente entre 0,3 e 0,6 e depende do ângulo de atrito interno do produto. Como a pressão vertical, a horizontal também tende a um valor assintótico com a profundidade, pelo mesmo efeito de atrito de parede. A pressão horizontal é decisiva para a espessura e a armadura das paredes de silos de concreto e para a chaparia de silos metálicos. Um ponto crítico: ela aumenta significativamente durante a descarga do produto (sobrepressão dinâmica), por causa da redistribuição de tensões no fluxo — e ignorar isso é uma causa clássica de ruptura de silos, razão pela qual as normas aplicam fatores de majoração sobre a pressão estática. Informe o peso específico, o diâmetro, o coeficiente de atrito, a relação de pressão lateral e a profundidade.
Related Tools
Silo Asymptotic Pressure
Calculate the asymptotic (saturation) vertical pressure of a deep silo, p_∞ = (γ·D) ÷ (4·μ·K), from the product unit weight γ, diameter D, product-wall friction coefficient μ and lateral pressure ratio K. This is the LIMIT value the Janssen vertical pressure tends to at great depth — the maximum bottom pressure a silo can reach, however tall the stored product. It is Janssen's most striking result: while in a liquid pressure would grow without limit with height (p = γ·h), in granular product WALL FRICTION absorbs all added weight beyond a certain depth, making bottom pressure SATURATE. So a 30 m silo of grain may have a bottom pressure equal to only a few metres of product column. This asymptotic pressure is fundamental in design: it sets the maximum bottom and wall load the structure must bear, regardless of height, and explains why silos can be built slender and tall with relatively modest foundations. Note it is proportional to diameter and inversely proportional to friction — wide, smooth-walled silos generate higher pressures. Enter the unit weight, diameter, friction coefficient and lateral pressure ratio.
Silo Vertical Pressure (Janssen)
Calculate the vertical pressure of stored product at a silo cross-section by the Janssen equation, p_v = (γ·D)/(4·μ·K)·(1 − e^(−4·μ·K·z/D)), from the product unit weight γ (N/m³), silo diameter D (m), product-wall friction coefficient μ, lateral pressure ratio K and depth z (m). The Janssen equation (1895) is the basis of silo structural design and reveals a counterintuitive, fundamental fact: pressure at the bottom of a silo does NOT grow indefinitely with product height like a liquid (p = γ·h). Instead it tends to a LIMIT (asymptotic) value. This is because granular product (grain, cement, ore) transmits part of its weight LATERALLY to the walls, and product-wall friction 'holds' that load, relieving the bottom. The deeper it goes, the larger the fraction of weight carried by wall friction, until all added weight is absorbed by the walls and bottom pressure stabilizes. So silos can be very tall without bottom pressures proportional to height. This arching and wall-friction effect is the heart of silo design. Enter the unit weight, diameter, friction coefficient, lateral pressure ratio and depth.
Janssen Characteristic Depth
Calculate a silo's Janssen characteristic depth, z₀ = D ÷ (4·μ·K), from the diameter D, product-wall friction coefficient μ and lateral pressure ratio K. The characteristic depth governs how fast silo pressures approach their asymptotic (limit) value: in the Janssen equation, it is the depth at which pressure reaches about 63% (1 − 1/e) of the maximum. Depths of a few times z₀ practically reach the limit pressure. Conceptually, z₀ shows how 'deep' the silo must be for wall friction to dominate: silos with small z₀ (small diameter, high friction) quickly reach the constant-pressure regime and behave as slender (tall) silos; silos with large z₀ (large diameter) saturate slowly and behave more like squat silos, where much of the weight still reaches the bottom. The characteristic depth is thus a natural measure of the vertical 'scale' of the silo's pressure behavior, useful to classify it and understand its load profile. Enter the diameter, friction coefficient and lateral pressure ratio.
The results provided by this tool are for general informational and educational purposes only and do not constitute professional, financial, medical, legal, tax or accounting advice. Always confirm important decisions with a qualified professional and official sources.