Pile Skin Resistance

Calculate a pile's side (friction) resistance, Q_l = f_s·A_s, from the average unit skin friction f_s (kPa) and the pile lateral surface area A_s (m², = π·D·L for a cylindrical pile). Side resistance is the share of pile capacity from FRICTION and ADHESION between the pile's lateral surface and the surrounding soil, along its whole buried length. As the pile tends to settle under load, the soil 'grips' its sides and resists — as a nail driven in wood resists pulling by face friction. The unit skin friction f_s depends on soil type (in clays, on undrained cohesion via the α method; in sands, on effective stress and friction via the β method), pile type (driven piles mobilize more friction than bored, displacing and compacting the soil) and surface roughness. Side resistance dominates in FLOATING (friction) piles, driven in soils without a firm bearing layer — they hang by friction. It is also the share mobilized FIRST under load (with small settlement), before the tip. This share adds to the tip resistance for the total capacity. Enter the unit skin friction and the side area.

Result

Resistência lateral de estaca

A resistência lateral (por atrito) de uma estaca é Q_l = f_s·A_s, a partir do atrito lateral unitário médio f_s e da área da superfície lateral A_s (= π·D·L para estaca cilíndrica). É a parcela da capacidade que vem do atrito e da adesão entre a superfície lateral da estaca e o solo ao seu redor, ao longo de todo o comprimento enterrado. À medida que a estaca tende a descer sob carga, o solo 'agarra' suas laterais e resiste — como um prego cravado na madeira resiste a ser puxado pelo atrito nas faces. O atrito lateral unitário f_s depende do tipo de solo (em argilas, da coesão não drenada via método α; em areias, da tensão efetiva via método β), do tipo de estaca (estacas cravadas mobilizam mais atrito que escavadas, pois deslocam e comprimem o solo) e da rugosidade. A resistência lateral é dominante em estacas flutuantes (de atrito), cravadas em solos sem camada firme de apoio — elas se sustentam 'penduradas' pelo atrito. É também a parcela que se mobiliza primeiro sob carga (com pequeno recalque), antes da ponta. Esta parcela soma-se à resistência de ponta para a capacidade total. Informe o atrito lateral unitário e a área lateral.

Related Tools

🪵

Pile Bearing Capacity

Calculate a pile's ultimate bearing capacity, Q_ult = Q_p + Q_l, summing the point (tip) resistance Q_p (kN) and the side (skin friction) resistance Q_l (kN). The pile is the DEEP foundation element used when surface soil lacks capacity for the structure's loads — it transfers loads to deeper, stronger subsoil layers. This transfer occurs by TWO mechanisms acting at once: TIP resistance (the pile bears on a firm layer at its base, like a column, mobilizing the soil resistance under the tip) and SIDE resistance (friction and adhesion between the pile's lateral surface and surrounding soil, along its whole length). Their proportion defines the behavior: END-bearing piles (crossing soft soil to bear on rock or firm soil) work mainly by the tip; FLOATING or friction piles (driven in homogeneous soil, no firm layer) work mainly by side friction. The ultimate capacity, divided by a safety factor (typically 2), gives the design allowable load. Determining Q_p and Q_l — by theoretical formulas, SPT-based semi-empirical methods (Aoki-Velloso, Décourt-Quaresma) or load tests — is the central deep-foundation design calculation. Enter the tip resistance and the side resistance.

⬇️

Pile Tip Resistance

Calculate a pile's tip resistance, Q_p = q_p·A_p, from the tip stress (bearing capacity) q_p (kPa) and the tip cross-sectional area A_p (m²). Tip resistance is the share of pile capacity from the BEARING of its base on a strong soil or rock layer — the pile acts as a column compressing the soil under its tip, mobilizing that soil's bearing capacity (like a shallow foundation, but at depth). The tip stress q_p is the soil's unit bearing capacity at the tip elevation, estimated by bearing-capacity theories (Terzaghi, Meyerhof, Vesic for piles), SPT correlations (q_p = K·N, with K depending on soil and pile type) or the CPT (cone) test. Times the tip area, it gives the force the tip supports. Tip resistance dominates in piles reaching a firm layer (end-bearing piles), and then the pile is very stiff (settles little). Large-diameter piles (caissons) have large tip areas and mobilize high tip resistance. This share adds to the side resistance for the total capacity. Enter the tip stress and the tip area.

Pile Allowable Load

Calculate a pile's allowable (working) load, Q_adm = Q_ult ÷ FS, from the ultimate bearing capacity Q_ult (kN) and the global safety factor FS. The allowable load is the maximum load that can be applied to the pile in service with adequate safety — obtained by dividing the ultimate capacity (the load that would cause FAILURE of the pile-soil system) by a safety factor covering uncertainties. The pile-foundation safety factor is typically HIGH (FS = 2.0-2.5 for ultimate capacity, higher if based only on theoretical formulas without a load test), reflecting the great uncertainty in determining soil capacity (unseen, heterogeneous and poorly known) and the severity of a foundation failure (which can collapse the whole structure). Codes often require different partial factors for tip and friction (which have different uncertainties), or limit-state methods. The allowable load sets how many piles are needed for the column loads: number of piles = column load ÷ allowable load. Load tests (measuring real field capacity) allow reducing the safety factor and optimizing design. Enter the ultimate capacity and the safety factor.