Leverett J-Function
Calculates the Leverett J-function, which normalises capillary pressure by interfacial tension, contact angle and the square root of the permeability-to-porosity ratio. It collapses capillary pressure curves from samples with different properties onto a single rock-type curve. Enter the capillary pressure, interfacial tension, contact angle, permeability in millidarcy and porosity.
Result
—
Collapsing capillary pressure curves onto one rock-type
The lab hands back one capillary pressure curve per core plug, and every plug carries its own permeability and porosity. Stacking those curves on a single chart yields a shapeless cloud: the 500 mD sample rises early, the 5 mD sample rises late, and the petrophysicist cannot pull a single saturation function out of it to feed the static model. The J-function exists to strip out what belongs to the sample and keep what belongs to the rock-type.
J = Pc / (σ·cos θ) × √(k/φ), where Pc means capillary pressure in Pa, σ the interfacial tension in N/m, θ the contact angle in degrees, and k the absolute permeability, entered in millidarcy and converted internally to m² through the factor 9.869233×10⁻¹⁶; φ goes in as a fraction. The values already loaded, 35000 Pa, 0.025 N/m, 30°, 120 mD and 0.22, give J = 1.1861. Most of a sandstone saturation range falls between 0.1 and 10. Anyone working in field units will recognise the same expression written as J = 0.2165 × Pc[psi] / (σ[dyne/cm]·cos θ) × √(k[mD]/φ).
The J-function delivers what it promises only inside one rock-type: collapsing clean sandstone curves together with vuggy carbonate curves builds no master curve, just a second cloud. The square root of k/φ stands as a crude proxy for pore throat radius, and it breaks down precisely where the throat size distribution turns bimodal. Contact angle has to stay under 90°: past that the cosine flips sign, the system reads oil-wet, the normalisation loses meaning, and the page refuses to calculate. Porosity goes in as a fraction, never a percentage — typing 22 instead of 0.22 triggers the same rejection, which at least makes the slip visible on the spot.
Frequently asked questions
Why does permeability go in as millidarcy when the formula wants m²?
Can I leave the contact angle at zero?
Does the tool build the full J curve against saturation?
Related Tools
Absolute Permeability by the Timur Correlation
Estimates the absolute permeability of a sandstone from porosity and irreducible water saturation, when no core sample is available for laboratory testing. The Timur correlation (1968), fitted on 155 Alaskan sandstone samples, is k = 0.136 × porosity^4.4 ÷ irreducible saturation², with permeability in millidarcy. The result tells how well the reservoir can flow: below 1 mD the formation is considered tight, between 10 and 100 mD it is moderate and above 500 mD it is excellent. The convention that causes most errors here is the unit: the constants 0.136 and 4.4 were fitted with porosity and saturation in percent, not as fractions — entering 0.22 instead of 22 drops the result by several orders of magnitude, which is why both fields ask for percent. Enter the effective porosity and the irreducible water saturation.
Water Saturation (Archie)
Compute a reservoir's water saturation (Sw) by Archie's equation (with a=1, m=2, n=2), Sw = √(Rw/(φ²·Rt)), from the formation-water resistivity (Rw), the rock's true resistivity (Rt) and the porosity (φ). It is the fundamental petrophysics equation: it relates the resistivity measured by electric logs to the fraction of pores filled with water — and, by complement (1−Sw), with hydrocarbons. Enter Rw, Rt and the porosity.
Volume/Capacity Ratio (V/C)
Calculate the volume/capacity ratio (degree of saturation), X = V ÷ C, dividing the traffic volume V by the capacity C of the road or intersection. The dimensionless result measures the road's utilization: X near 0 indicates a free road; X = 1 means the road operating exactly at capacity; X > 1 indicates demand above capacity, with growing queues and congestion. The V/C ratio is the main indicator to classify the level of service (LOS A to F) and identify bottlenecks. Values above 0.85–0.90 already indicate near-saturation operation. Enter the volume and the capacity.
Water Tank Volume Calculator
Compute rectangular and cylindrical water tank volume in liters. Suggests minimum size for N people (200L/day/person).
Fire Water Reserve (RTI)
Calculate the fire water reserve volume, V = flow × time ÷ 1000, multiplying the system's required flow (L/min) by the required autonomy time (min) and converting to cubic metres. The result, in m³, is the water volume the tank must keep reserved exclusively for firefighting — sized to feed hydrants and/or sprinklers for the minimum time set by codes (typically 30 to 60 min, depending on risk). It is a central calculation in building firefighting installation design. Enter the flow and the autonomy time.
Saturation Flow
Calculate the saturation flow of a signalized approach, S = S₀ × N, multiplying the base saturation flow per lane S₀ (vehicles/h per lane, typically ~1800–1900) by the number of lanes N. The result, in vehicles/h, is the maximum rate of vehicles that can cross the stop line if the signal stayed green continuously and a queue existed — the queue discharge rate during green. It is a central parameter in signal design and intersection capacity, adjusted by lane width, grade, turning and parking factors. Enter the base saturation flow per lane and the number of lanes.