1001Ferramentas
Calculators

Faradaic Efficiency

Calculate the faradaic efficiency (current efficiency), η = (m_actual ÷ m_theoretical) × 100%, comparing the mass of product actually deposited or consumed with the theoretical mass predicted by Faraday's law for the charge that passed. The result, in %, measures what fraction of the current was actually used in the desired reaction; the rest is lost to side reactions (such as hydrogen or oxygen evolution) or short circuits. It is a key indicator in electrodeposition, industrial electrolysis, electroplating and batteries. Enter the actual mass obtained and the theoretical mass.

Result

Eficiência faradaica

A lei de Faraday prevê exatamente quanta massa deveria ser depositada, dissolvida ou produzida numa reação eletroquímica para uma certa quantidade de carga elétrica que passa. Na prática, porém, nem toda a corrente vai para a reação que queremos — parte se desvia para reações paralelas. A eficiência faradaica (ou eficiência de corrente) mede esse aproveitamento: η = (m_real ÷ m_teórica) × 100%, a razão entre a massa realmente obtida e a massa teórica calculada por Faraday para a mesma carga. Uma eficiência de 90% significa que 10% da corrente foi 'desperdiçada'. Os ladrões de corrente mais comuns são o desprendimento de hidrogênio no cátodo e de oxigênio no ânodo (eletrólise indesejada da água), reações de espécies secundárias e correntes de fuga. O conceito é central em várias indústrias: na galvanoplastia e eletrodeposição (quanto do banho vira revestimento), na eletrólise industrial (produção de alumínio, cloro-soda — onde cada ponto percentual significa enormes custos de energia), e em baterias (a eficiência coulômbica, que mede quanta carga injetada é recuperada na descarga, é a mesma ideia). Informe a massa real obtida e a massa teórica.

Related Tools

⚗️

Bath Throwing Power (Haring-Blum)

Computes the throwing power of an electroplating bath from the Haring-Blum cell test, TP = 100 × (K − M) ÷ (K + M − 2), where K is the ratio of anode-to-cathode distances — the standard cell uses 5 to 1 — and M is the ratio between the mass deposited on the near cathode and the mass deposited on the far cathode. The number, as a percentage, measures how well the bath equalizes deposit thickness across areas of unequal access, such as recesses, holes and the inside of stamped parts, despite the difference in electrolyte resistance between the two paths. When M equals K the metal distributed exactly as the geometry predicted and throwing power is zero; when M reaches 1 both cathodes receive the same mass and the result is 100%; negative values appear when the bath deposits even less on the far cathode than geometry alone would predict, the notorious case of chromium baths. Alkaline and cyanide baths usually score best and bright acid baths worst, which is why picking the electrolyte matters more than raising the current when the part has awkward geometry. Enter the cell distance ratio and the ratio between the deposited masses.

💧

Gross Irrigation Depth

Calculate the gross irrigation depth, D_gross = D_net ÷ Ef, dividing the required net depth (the water that must reach the roots, in mm) by the irrigation system's application efficiency (decimal). The result, in mm, is the depth the system must actually apply so that, after losses (evaporation, drift, percolation, runoff), the net depth remains in the soil. More efficient systems (drip, ~90%) require less gross depth than less efficient ones (conventional sprinkler, ~75%; surface, ~50-60%). It is the basis of irrigation design and management. Enter the net depth and the application efficiency.

🛡️

Vibration Isolation Efficiency

Calculate the vibration isolation efficiency, I = (1 − TR) × 100%, from the transmissibility TR. The result, in %, shows how much of the source vibration is blocked by the isolator before reaching the supporting structure (or vice versa): TR = 0.1 corresponds to 90% isolation. High efficiencies require soft isolators (low natural frequency), so that the frequency ratio r is well above √2. It is the practical indicator to specify mounts and antivibration bases for machines, engines and sensitive equipment. Enter the transmissibility.

📉

Tafel Overpotential

Calculate the activation overpotential by the Tafel equation, η = a + b × log₁₀(i), from the Tafel constant a (V), the Tafel slope b (V/decade) and the current density i. The result, in volts, is the overpotential — how far an electrode's potential departs from equilibrium — needed to sustain a given current density in an activation-controlled electrochemical reaction. The Tafel relation is central to electrode kinetics, corrosion (extrapolation to obtain the corrosion current) and electrolysis. Enter the Tafel constant, slope and current density.

🔋

Energy per Elevator Trip

Calculate the potential energy spent to raise a load, E = m·g·h, from the unbalanced mass m (net load after the counterweight, kg), gravity g and the lift height h (m). The result, in joules, is the minimum theoretical energy to hoist the load — a basis for estimating the elevator's electrical consumption and the energy-regeneration potential. Modern elevators with regenerative drives recover part of this energy on descent (when the counterweight descends with a light car), feeding it back to the grid. Actual consumption is higher, divided by the efficiency. Enter the unbalanced mass and the lift height.

📊

Resource Utilization Calculator

Compute resource utilization (CPU, machine, person) — busy time / total available time. Shows efficiency and idle time.

The results provided by this tool are for general informational and educational purposes only and do not constitute professional, financial, medical, legal, tax or accounting advice. Always confirm important decisions with a qualified professional and official sources.